High Pressure Magnetic Flow Meter |16MPa-25MPa-35MPa-42MPa

High Pressure Magnetic Flow Meter

LDG series High Pressure Magnetic Flow Meter is used to measure the volume flow of conductive fluids in closed pipes. This high-pressure flowmeter adopts excitation technology, and the conversion efficiency of the excitation circuit is extremely high, which is suitable for the measurement of polymer solutions for polymer injection in oil fields.

Especially for the flow measurement of high-pressure pipelines, the stability is higher. Can customized meet 1.6MPa; 2.5MPa; 6.4MPa; 16MPa; 25MPa; 42MPa.

Features of High Pressure Magnetic Flow Meter

  • Customized pressure: 1.6MPa; 2.5MPa; 6.4MPa; 16MPa; 25MPa; 42MPa
  • Adopting the internationally leading excitation technology, the excitation circuit conversion efficiency is extremely high and the stability is higher.
  • High-resistance fast response circuit, non-distortion acquisition of weak signals and rapid response to flow changes.
  • Large screen multi-parameter synchronous display, instantaneous flow, flow rate, net accumulation, total forward and reverse accumulation, and alarm, etc.
  • Ex explosion-proof design, in line with national explosion-proof technical requirements, can be used in explosion-proof places.
  • A wide range of power supply modes are available (DC: 18V~36V AC: 85V~265V).
  • With lightning protection design circuit. High-efficiency anti-interference circuit, suitable for various harsh environments.
  • A variety of output communication interfaces are available: 16-bit digital current loop 4~20mA output, KHz frequency output, pulse equivalent output, alarm output, RS485 communication interface.

Technical parameters

Range ratio:1:10, 1:20
Flow rate range:0.1 ~ 10 m/s
Medium conductivity:>5us/cm
Measurement accuracy:±0.5%, ±1.0%
Display mode:LCD displays instantaneous flow, forward and reverse net cumulative totals, and various alarms.
Medium temperature:0 ~ 70℃; 0 ~ 120℃; 0 ~ 180℃ (optional)
Pressure:1.6MPa; 2.5MPa; 6.4MPa; 16MPa; 25MPa; 42MPa
Ambient temperature:‘-20℃~+50℃
Relative humidity:5%~90%
Mechanical vibration frequency:≤55Hz Amplitude: ≤0.15mm
Protection level:IP67 or IP65
Power supply:85 ~ 265VAC or 18 ~ 36VDC
Rated power:Less than 10W
Repeatability±0.1% of measured value
Output signal (all isolated)1. Current 4~20mA Load less than 750Ω
2. Frequency 0~5kHz Amplitude 24V Active or passive
3. Pulse equivalent
4. RS485
5. HART (optional)
Excitation mode1) Three amplitude low frequency excitation
2) High frequency excitation
3) Specific excitation
Time constant0~60 seconds can be set
Pipeline connection modeUnion type: DN≤40mm high and low pressure and DN=50mm low pressure
Clamp type: 50≤DN≤80mm high pressure
Flange type: DN≥50mm low pressure
Flange clamp type: DN≥80mm low pressure

Optional materials:

Lining materialPolyurethane≤80℃ Neutral strong wear ore slurry, mud, coal slurry
Corrosion-resistant rubber≤60℃ General acid, salt, alkali solution, good wear resistance
PTFE≤180℃ Concentrated acid, alkali, strong corrosive medium
F46≤120℃ Sewage, seawater, acid, salt, alkali solution
Electrode materialStainless steelNitric acid, sulfuric acid <5% at room temperature, boiling phosphoric acid, formic acid, alkali solution, sulfite seawater under a certain pressure, acetic acid and other media have strong corrosion resistance and are used in petrochemical, urea and other industrial occasions
Hastelloy HBGood corrosion resistance to all acids below the boiling point, and also resistant to corrosion of non-oxidizing acids, alkalis, and non-oxidizing salt solutions such as sulfuric acid, phosphoric acid, hydrofluoric acid, and organic acids
Hastelloy HCCan resist corrosion from nitric acid, mixed acid, or mixed media of chromic acid and sulfuric acid, and also resistant to corrosion from oxidizing salts, or hypochlorous acid solution seawater above normal temperature
Special materialsSpecial requirements

Flow Range:

Nominal diameter DN (mm)Flow range m³/hMaximum measuring range  m³/h
100.125-2.50.028-2.83
150.3-60.064-6.37
250.8-160.177-17.7
321.4-280.29-29
402-402.5-50
502.5-503.5-70
805-1009-180
10010-20014-280
15025-50030-600
20045-90011.3-1130
25070-140017.7-1770
300100-200025.5-2550
35083-277634.7-3470
400200-400045.3-4530
500300-600070.8-7080
600245-8152101.9-10190
700333-11096138.7-13870
800435-14488181.1-18110
1000679-22640283-28300
1200978-32600407.5-40750

Read more about: How does a magnetic flow meter work?

application range of Electromagnetic high pressure flowmeter

The electromagnetic high pressure flowmeter is a versatile device used to measure liquid flow in various industries. Its application range includes water treatment, chemical processing, oil and gas, power plants, and food production. This flowmeter is designed for high pressure situations, making it suitable for pipelines and systems with demanding conditions.

The electromagnetic high pressure flowmeter is used in industries such as:

Water treatment: Measuring flow in high-pressure pipes for clean water distribution.
Example: Monitoring flow rates in a water treatment plant’s main supply line.

Chemical processing: Controlling flow of aggressive or corrosive liquids in high-pressure systems.
Example: Measuring the flow of acids in a chemical manufacturing plant.

Oil and gas: Monitoring flow in high-pressure pipelines for oil or natural gas transport.
Example: It is suitable for the metering of polymer solutions for polymer injection in oilfields.

Power plants: Managing cooling water flow in high-pressure systems. Example: Measuring coolant flow in a nuclear power plant’s reactor cooling system.

Food production: Ensuring accurate flow measurements in high-pressure food processing systems.
Example: Monitoring flow of liquid chocolate in a confectionery factory’s high-pressure pipeline.

Other types of high pressure flow meters for liquids

Other types of high pressure flow meters for gases

Frequently
Asked
Questions

A high pressure flow meter is a device that measures the flow of liquids or gases in high-pressure systems. It is designed to handle demanding conditions, ensuring accurate flow measurements in various industries like water treatment, chemical processing, and oil and gas.

A high flow meter is designed for measuring high flow rates and high-pressure systems, while a low flow meter is for measuring low flow rates and low-pressure systems. The main difference lies in their pressure handling capabilities and flow rate ranges.

For high-pressure water systems, a high pressure electromagnetic flowmeter is suitable. It can accurately measure flow rates in high-pressure water pipelines, ensuring reliable and consistent readings.

To measure high flow rates, you need a high flow meter designed for high-pressure systems. Common types include electromagnetic, ultrasonic, and turbine flow meters. The choice depends on factors like the fluid type, required accuracy, and system conditions.

More Flow Measurement Solutions

We explored the world of electromagnetic high pressure flowmeter. A game-changing technology for accurate flow measurement in demanding applications.

As a professional supplier with extensive experience, Sino-Inst offers a wide range of electromagnetic high-pressure flowmeters with pressure ratings from 0.6 MPa to 42 MPa.

Our electromagnetic high pressure flowmeters are designed to meet the specific needs of various applications, ensuring precision and reliability. To learn more about our products and how they can benefit your operations, please visit our website or get in touch with our expert team. Discover how Sino-Inst’s electromagnetic high-pressure flowmeters can revolutionize your flow measurement and optimize your processes today!

    Request For Quote