Tank Level Measurement with Pressure Transmitters/DP Transmitters

Tank Level Measurement with DP Transmitters

Pressure transmitters and differential pressure transmitters can be used to measure the level of liquids such as water or fuel in vented or sealed tanks. And in many special working conditions, it has advantages that other liquid level transmitters cannot match. For example, the measurement of viscous, high-temperature, corrosive liquids or gases in vacuum tanks.

Measurement principle:

Tank Level Measurement is realized using a pressure transmitter or a differential pressure transmitter, both of which apply the static pressure principle of liquids.

The static pressure at a certain point in the liquid is proportional to the distance from the point to the liquid surface, that is: P = ρgh.

Hydrostatic pressure measurement principle

Among them: P-the pressure (pressure) of the measured point, ρ-medium density, g-gravitational acceleration, h-height from the measured point to the liquid surface.

For the determined measured medium ρ, g is a constant, so the change in the position of the measured point to the liquid surface is only related to the measured P pressure (pressure).

When measuring liquid level in an open container, a pressure transmitter is all you need.

When measuring the liquid level of a closed pressure vessel, you can consider using two pressure or one differential pressure transmitter, that is, one for lower limit measurement and one for upper limit measurement. Their output signals are subtracted to measure the liquid level. When the liquid level and pressure in the container remain unchanged, it can also be used to measure the density of the medium.

For differential pressure transmitters,

Let △P be the differential pressure signal received by the transmitter, P0 be the internal pressure of the container, P+ be the positive pressure side pressure of the transmitter, P- be the negative pressure side pressure of the transmitter; ρ be the density of the liquid in the container; g is the acceleration of gravity; h1 is the height from the process zero point to the pressure port on the upper part of the container; h2 is the process liquid level of the container; h is the height from the transmitter to the zero point of the process liquid level.

Then there are:
P+=P0+ρgh1+ρgh
P-=P0+ρgh2+ρgh
△P=P+-P-=ρgh1-ρgh2

When the liquid level changes from h2=0 to h2=h1, the differential pressure measured by the differential pressure transmitter changes from a large value to ΔP=0. By setting the transmitter, the output current changes from 4mA to 20mA.

Read more about: Differential Pressure Level Transmitter: Understanding, Principles and Uses

Level measurement in vented/open tanks

Level measurement in vented open tanks

Open tank level measurement means the tank is open to the atmosphere. Any change in atmospheric pressure will affect the process fluid pressure inside the tank.

Use a pressure transmitter to measure the liquid level of vented/open tanks. Generally, the pressure transmitter is installed lower in the tank or connected to the pressure at the bottom of the tank. The transmitter can be equipped with a flange or a pressure pipe.

Of course, if the medium conditions permit, such as water measurement, then it may be cheaper to use a simple submersible level transmitter.

Single flange liquid level transmitter survey mode: For viscous liquids or coagulable liquids, an isolation diaphragm should be added at the entrance of the pressure guiding pipe, and silicone oil should be filled in the pressure guiding pipe to transmit pressure with the help of silicone oil.

Sealed Tank Level Measurement

Sealed tank Level Measurement

For closed vessels, because the interior is isolated from the atmosphere, the pressure within the tank may change from positive pressure to a vacuum when the process fluid fills or empties the tank. This change in tank pressure will directly affect the measured level unless compensated for. This is done by connecting the low side pipe of the differential pressure transmitter to the top of the tank. Therefore, when measuring the liquid level of a closed tank, a differential pressure transmitter must be used.

The media in chemical production often encounter problems such as impurities, crystallized particles or agglomeration, which can easily block the connecting pipeline. In this case, a flange-type differential pressure transmitter can be used. The closed system composed of a membrane box, a capillary tube, and measuring chamber is filled with silicone oil, which serves as a pressure transmission medium to prevent the measured medium from entering the capillary tube and transmitter to avoid clogging.

Example of calculation

Assume that ρ medium is the medium density = 1.5, ρ0 is the silicone oil density = 0.93, H0 is the medium mass range 0-5m, H1 = 1m, H2 = 6m. The double flange level gauge is installed below the horizontal line of the lower end flange of the closed vessel. Let’s calculate the measuring range of the differential pressure transmitter.

Measuring range: ΔP=ρ×g×H0=1.5×9.8×5=73.5KPa

High-pressure side empty liquid level pressure: P(+)=ρ0×g×H1=0.93×9.8×1=9.114KPa

Low-pressure side empty liquid level pressure: P(-)=ρ0×g×H2=0.93×9.8×6=54.684KPa

Pressure difference when the liquid level is empty: ΔP= P(+)-P(-)=9.114-54.684=-45.57KPa

Pressure difference when full liquid level: ΔP=empty liquid level pressure difference ΔP+range value ΔP=-45.57+73.5=27.93KPa

Therefore, the measuring range of the differential pressure transmitter is: -45.57 to 27.93KPa

Example of calculation

Featured Pressure Transmitters/DP Transmitters for Tank Level Measurement

When measuring liquid levels in a tank using a pressure transmitter or differential pressure transmitter, it is generally necessary to select accessories such as a sealing diaphragm and a capillary tube. You can learn more about this further:

Advantages of Pressure/Differential Pressure Hydrostatic Level Measurement

Using pressure transmitters and differential pressure transmitters to measure tank liquid level can meet many special working conditions. For example:

  • Larger size tanks;
  • High temperature medium;
  • Highly viscous media;
  • Extremely low temperature medium;
  • Corrosive media;
  • Volatile media, etc.

Of course, different measurement media and tank parameters will have an impact on the selection of the transmitter. Including diaphragm material, specifications, thickness, filling liquid type, capillary length, and inner diameter, etc. Various factors should be considered comprehensively when selecting.

More Tank Level Measurement Solutions

External Ultrasonic Level Meter for Liquid Tanks

The External Ultrasonic Level Meter enables truly non-contact measurement of liquid levels in closed containers. The ultrasonic sensor (probe) is installed just below (bottom) the outer wall of the container being tested. There is no need to drill holes in the container being tested. It is easy to install and does not affect production. The … Read more

Sulfuric Acid Storage Tank Level Measurement

In industries such as chemical engineering, metallurgy, pharmaceuticals, electroplating, and sulfuric acid storage and transportation, sulfuric acid, as a basic raw material, is extremely corrosive. 98% concentrated sulfuric acid is viscous, fuming, and easily releases volatile acid mist. Under certain operating conditions, it is also accompanied by complex conditions such as high temperature and crystallization. … Read more

Different Diesel Level Sensors for Diesel Tank Level Measurement

Diesel sensors can be used to measure the liquid level of diesel in storage tanks and convert it into standard electrical signals or switching signals. It can be used to build a diesel storage tank liquid level monitoring system. Sino-Inst supplies float, ultrasonic, radar and other various diesel level sensors. Supports customization of measuring range, … Read more

Capacitive Oil Level Sensor for Truck and Industrial Tanks

The capacitive oil level sensor is a liquid level sensor based on the radio frequency capacitance measurement principle. It can be installed in various occasions to accurately measure the oil level of gasoline, diesel, hydraulic oil and other weakly corrosive liquids. The length can be customized according to customer requirements. It can output 4~20mA, 0~5V … Read more

Liquid Nitrogen Cryogenic Tank Level Monitoring

When using liquid nitrogen tanks, it’s crucial to constantly monitor the liquid nitrogen level inside. Replenishing the tank as needed ensures the sample remains at a constant -196°C, preserving its activity. Generally, replenishment is necessary when the level drops below one-third. Insufficient liquid nitrogen will prevent complete coverage of the sample, causing the internal temperature … Read more

Liquid Level Controllers and Switches for Industrial Tanks

What is Liquid Level Controller? Liquid level controller refers to the control of high and low liquid levels through mechanical or electronic methods. Can control solenoid valves, water pumps, etc. Used to monitor fluid levels and ensure fluids remain at set levels. This enables semi-automatic or full automation of tank liquid level monitoring and control. … Read more

Liquid Nitrogen Pressure Measurement – Pipeline and Tank

Measuring the liquid nitrogen pressure and temperature places high demands on the sensor. The temperature of liquid nitrogen can reach as low as -196°C, which requires the temperature transmitter, pressure transmitter, and flow meter to work normally at -198°C. Sino-Inst’s low-temperature pressure transmitters can effectively meet the pressure measurement of liquid nitrogen pipelines and liquid … Read more

In many Tank Level Measurement working conditions, we will first use the liquid level transmitter. For example, an ultrasonic level meter, a radar level meter, etc. Pressure transmitters and differential pressure transmitters also have incomparable advantages. If you need to perform Tank Level Measurement and have related purchasing needs, please feel free to contact our sales engineers!

    Request For Quote