The main function of the Digital Diesel Flow Meter is to accurately measure the volume or mass flow rate of diesel fuel, providing high-precision digital display and supporting signal output.
Local digital display function, real-time display of instantaneous flow rate, cumulative flow rate, etc. It can significantly improve the flow meter’s range ratio and measurement accuracy.
Advantages of Digital Display
Clearer Readings
The Digital Diesel Flow Meter directly displays instantaneous and cumulative flow values with high accuracy, precise to three decimal places. Compared to mechanical pointer or counter wheel displays, which require manual reading and calculation, the digital display provides clearer and simpler readings.
Higher Accuracy
The digital flow meter only requires adjustment of the flow coefficient. The flow coefficient varies at different flow rates, especially at minimum flow rates, which affects its rangeability. The electronic display can effectively overcome this by using flow rate segmentation for comparison.
The Digital Diesel Flow Meter can improve flow accuracy to 0.25%.
Of course, digital displays have many more advantages.
Featured Display
Digital diesel flow meters can visually display instantaneous flow rate and cumulative flow. Some customized models can also display information such as pressure, temperature, frequency, and power supply.

Digital Diesel Flow Meter Types
Commonly used digital diesel flow meters in industrial applications include oval gear flow meters, turbine flow meters, GF gear flow meters, and mass flow meters.
Oval Gear Flow Meter
Oval gear flow meters can be customized with mechanical or electronic displays. They are available in cast iron, cast steel, and stainless steel materials. They offer stable and reliable measurement with accuracy up to 0.5% or 0.2%. Furthermore, they do not require any specific straight pipe length for installation.
| Diameter | DN10~DN200 |
| Accuracy | Class 0.5 or 0.2 |
| Temp. range | -20℃-+100℃ |
| Pressure | 1.0MPa、1.6MPa、2.5MPa、4.0MPa、6.4MPa |
| Medium | High viscosity liquid and All kinds of oil |
| Explosion-proof | iaⅡCT5,dⅡBT4 |


Turbine Flow Meter
The turbine flow meter is a low-cost diesel fuel flow meter. It offers an accuracy of up to 0.5%. It can tolerate small amounts of impurities in the measured liquid. High-pressure versions up to 40 MPa are available upon request.
| Diameter | DN4-DN200 |
| Accuracy | Class 1.0, class 0.5 |
| Temp. range | -20~+150℃ |
| Flange standard | GB/T 9119-2010, DIN, ANSI, JIS |
| Output | Pulse, 4-20mA analog output,RS485 (Modbus-RTU protocol), HART |
| Explosion proof | ExdIIBT6 (explosion proof type) |
GF Gear Flow Meter
The GF series gear flow meter is a flow meter specifically designed for measuring very small diesel fuel flow rates. It boasts an accuracy of 0.5%, and the minimum flow rate measurement can be customized down to 0.1 L/H. It also supports customization for high temperatures up to 200℃ and high pressures up to 40 MPa. Available materials include aluminum alloy, stainless steel, and PTFE.
| Measurement range: | Minimum measurable flow rate: 0.1 L/h, Maximum measurable flow rate: 10000 L/h |
| Accuracy: | 0.50% |
| Signal output: | Pulse, 4-20mA, and RS485 communication; 0-5V is optional. |
| Temperature resistance: | -200℃~ +200℃ |
| Pressure resistance: | 1.6MPa, 2.5MP,15MPa, 25MPa, 32MPa, 40MPa |
| Explosion-proof: | Exd IICT6 |


Mass Flow Meter
Coriolis mass flow meters are the most accurate diesel fuel flow meters, with an accuracy of up to 0.1%. They are widely used for diesel fuel trade metering. However, Mass flow meters are relatively high-cost.
| Measuring diameter range: | DN6~DN200 |
| Fluid measurement accuracy: | ±0.1~0.2% |
| Density measurement range: | 0.3~3.000g/cm3 , accuracy: ±0.002g/cm3 |
| Working temperature of measured medium: | Standard type: -50~200℃ High temperature type: -50~350℃ Low temperature type: -200~200℃ Measurement accuracy: ±1℃ |
| Working pressure: | 0~4.0MPa (high pressure can be customized) |
| Explosion-proof standard: | Exd(ia)IICT6Gb |
Technical Support
Selection Guide
Based on our years of experience in flow measurement, we recommend that you consider the following parameters when choosing a suitable Digital Diesel Flow Meter:
- Pipe diameter
- Flow range: including minimum, normal, and maximum flow rates
- Compatibility of flow range and pipe diameter
- Pressure in the pipeline
- Diesel temperature
- Viscosity
- Installation location and straight pipe section requirements: Oval gear flow meters, GF gear flow meters, and mass flow meters do not require straight pipe sections before and after installation. Turbine flow meters do.
- Power supply availability: 24VDC or 220VAC?
- Required measurement accuracy
- Whether remote monitoring of flow is needed
- Cost budget
By considering all the above details, you can select the appropriate Digital Diesel Flow Meter.
If you still have questions or cannot select a suitable Digital Diesel Flow Meter, please feel free to contact our sales engineers! We will provide you with selection and pricing based on your measurement parameters.