SI-3109 Electromagnetic Flow meter for large diameter pipe,
which is electronics flow meter for large diameter pipe recycling water meter.
SI-3109 Magnetic flow meter can be used as Sewage flow meter for water flow rate measurement. For industrial waste water treatment, magnetic flow meter is your best choice. Because we can choice different material for electrode and lining.
Diameter | DN6~DN2200mm |
Accuracy | ±0.5% |
Flow rate | 0.3~10m/s |
Electrode | 316L (Suitable for domestic water, industrial water, raw water, underground water, sewage, etc.; not applicable to acid and alkali salt) |
Lining material | Chloroprene rubber(CR), polyurethane rubber(PU) |
Features
Specifications
Order Guide
Applications
Reviews
Features
SI-3109 Large Diameter Pipe – Electromagnetic Flow Meter for Sewage/Wastewater,
is composed of insertion electromagnetic sensor and electromagnetic flow converter,
used to measure the conductive liquid that electrical conductivity is greater than 5 us/cm,
it is used to measure the water, sewage, acid, alkali and other medium.
Suitable for measuring the large pipe of diameter DN300~DN3000mm.
Installation can be divided into a online installation type of the cut-off valve,
and water control installation type without stop valves.
- Non-invasive, no moving parts flow sensing technology
- Accuracy 0.5% of actual flow
- Calibration pre-programmed to user’s specific applications
- Measures liquid flow in 2 to 36 inch
- Operates in high temperatures up to 170°F
Specifications
SI-3109 Electromagnetic flow meter | |
Medium | Domestic water, industrial water, raw water, ground water, urban sewage, industrial wastewater, the processed neutral pulp, pulp slurry, etc |
Diameter | DN6~DN2200mm |
Accuracy | ±0.5% |
Medium temperature | <60℃ |
Nominal pressure | GB 0.6MPa (DN700~DN2000) GB 1.0MPa (DN200~DN600) GB 1.6MPa (DN6~DN150) |
DIN PN16,PN25,PN40,PN63 | |
JIS10K,20K,40K | |
ANSI Class150,Class300,Class600, others can be customized | |
Flow rate | 0.3~10m/s |
Straight pipe required | Upstream ≥5DN,downstream ≥3DN |
Electrode | 316L (Suitable for domestic water, industrial water, raw water, underground water, sewage, etc.; not applicable to acid and alkali salt) |
Lining material | Chloroprene rubber(CR), polyurethane rubber(PU) |
Installation way | Carbon steel flange (standard), Stainless steel flange(optional) |
Body material | Carbon steel (standard),Stainless steel(optional) |
Power supply | 220VAC/24VDC/lithium battery |
Signal output | Pulse and 4~20mA; (if use lithium battery, without signal output) |
Communication | RS485,GPRS,Hart |
Explosion-proof | EXdeibmIICT3-T6 |
Protection proof | IP65 (compact type); IP67,IP68(suitable for remote type) |
Work environment | Ambient temperature:-20~+60℃,Ambient humidity:5%~90% |
Power | <20W |
Electrode material selection:
Material | Medium |
316L | Domestic water, industrial water, raw water, urban sewage, etc. |
Hastelloy B (HB) | Sodium hydroxide ammonium hydroxide alkali solution and weak organic acid |
Hastelloy C (HC) | Oxidizing salt solution (Fe+++, Cu++, seawater) |
Titanium (Ti) | 1. Salt solution (chloride, sodium salt, potassium salt, ammonium salt, sea water, etc.) 2. Alkaline solution (such as concentration less than 50% potassium hydroxide solution) |
Tantalum(Ta) | 1. Hydrochloric acid, sulfuric acid, oxidizing acid, aqua regia 2. Chlorine dioxide, ferric chloride, hypochlorous acid, sodium cyanide, lead acetate, etc. |
Platinum (Pt) | Acid, alkali, salt solution |
Tungsten carbide (WC) | Handled neutral industrial sewage and domestic sewage. Resistant to solid particle interference |
Lining material selection
Lining material | Linner | Temperature | Suitable medium | Diameter |
Rubber | Neoprene(CR) | -20~60℃ | Tap water,industrial water,seawater | DN65~DN1600 |
Natural Rubber(NR) | ||||
Polyurethane Rubber(PU) | Slurry, paper pulp etc. | DN25~DN500 | ||
Silicone rubber | -20~180℃ | Water | DN40~DN1600 | |
Fluoroplastic | PTFE(F4) | -20~120℃ | Corrosive acid-base salt liquid | DN10~DN1600 |
Teflon F46(FEP) | -40~160℃ | Corrosive acid-base salt liquid | DN10~DN200 | |
PFA | -40~160℃ | Corrosive acid-base salt liquid | DN10~DN300 |
Order Guide
SI-3109- | Note | ||||||||||||
Diameter | DNXX | DN6~DN2200(mm) | |||||||||||
Structure | F | Remote type (standard with 10m cable) | |||||||||||
Y | Compact type | ||||||||||||
Electrode | S | 316L | |||||||||||
T | Titanium(Ti) | ||||||||||||
D | Tantalum(Ta) | ||||||||||||
C | Hastalloy C(HC) | ||||||||||||
P | Platinum iridium alloy | ||||||||||||
Lining material | X | Chloroprene rubber (CR) Suitable for tap water, | |||||||||||
J | Polyurethane rubber (PU) Suitable for pulp, pulp, etc liquid | ||||||||||||
E | Polytetrafluoroethylene (PTFE) | ||||||||||||
A | PFA | ||||||||||||
Body material | CS | Carbon steel | |||||||||||
S4 | SUS304 | ||||||||||||
Protection class | L0 | IP65(compact type) | |||||||||||
L1 | IP67(remote type) | ||||||||||||
L2 | IP68(remote type) | ||||||||||||
Power supply | 1 | 110~240V AC | |||||||||||
2 | 24V DC | ||||||||||||
3 | Lithium battery(no signal output) | ||||||||||||
Signal output | N | No output | |||||||||||
N1 | 4-20m/pulse output | ||||||||||||
Communication | H | HART protocol | |||||||||||
R1 | MODBUS RS485 | ||||||||||||
G | GPRS | ||||||||||||
With grounding ring | 0 | Without grounding ring | |||||||||||
1 | With grounding ring | ||||||||||||
Nominal pressure | D1 | DIN PN16 | |||||||||||
D2 | DIN PN25 | ||||||||||||
D3 | DIN PN40 | ||||||||||||
D4 | DIN PN63 | ||||||||||||
J1 | JIS 10K | ||||||||||||
J2 | JIS 20K | ||||||||||||
J3 | JIS 40K | ||||||||||||
A1 | ANSI Class150 | ||||||||||||
A2 | ANSI Class300 | ||||||||||||
A3 | ANSI Class600 | ||||||||||||
O | Others | ||||||||||||
Cable length | /xx | Unit: m |
Applications
SI-3109 Large Diameter Pipe – Electromagnetic Flow Meter for Sewage/Wastewater.
Applications including:
water,
raw sewage,
wastewater,
clarified water,
RAS,
and WAS.
Available process connections include hot-tapped, DIN and NPT threads.
Reviews
March 21, 2019 at 10:08 pm
Amis
Good choice for large pipe.