Home > Level Transmitters > Portable Intrinsically Safe Ultrasonic Level Sensor for Tank Trucks

Portable Intrinsically Safe Ultrasonic Level Sensor for Tank Trucks

Portable Intrinsically Safe Ultrasonic Level Sensor

The Portable Intrinsically Safe Ultrasonic Level Sensor is a specialized instrument designed to measure the liquid level in tank trucks or monitor the presence of liquid at a specific location. It is specifically used by oil depot managers to check whether tank trucks contain residual liquid before they enter the tank farm to be filled with oil.

The Portable Intrinsically Safe Ultrasonic Level Sensor utilizes the principle of ultrasonic echo ranging. By employing advanced signal processing technology and high-speed signal processing chips, it achieves true non-contact measurement of liquid levels inside sealed containers and detects the presence or absence of liquid at a specific location.

Our Portable Intrinsically Safe Ultrasonic Level Sensor has passed testing in accordance with the GB3836.1-2021, GB3836.4-2021, GB3836.9-2021, with explosion-proof markings of Ex ib IIB T4 Gb (main unit) and Ex mb II T6 Gb (probe). It is suitable for Zone 1 and Zone 2 hazardous locations in industrial facilities containing explosive gas mixtures of Class IIA and IIB, Temperature Groups T1–T4.

Benefits

Technical Specifications

Repeatability Error:±2 mm
Measurable Wall Thickness:2–10 mm
Ambient Temperature:–20°C to +50°C
Ambient Humidity:15%–100% RH
Rated Voltage:3.6 V
Battery Specifications:Built-in potted lithium-ion battery pack, 18650/3500 mAh
Level Value or Status Display:6-digit OLED display
Continuous Operating Time:>8 hours
Product Dimensions:106.5 × 43.5 × 156 mm (main unit) / φ57 × 61 mm (probe)
Product Weight:350 g (main unit)
Suitable Tank Types:Horizontal tanks;
Measurable Media:Gasoline, diesel, edible oil, LPG, etc.

Suitable Container (Tank) Materials:

The container wall at the location where the ultrasonic probe is attached must be made of a hard material capable of effectively transmitting signals. Examples include carbon steel, stainless steel, various hard metals, fiberglass-reinforced plastic, epoxy resin, hard plastics, ceramics, glass, hard rubber, and other composite materials.

The inner and outer surfaces of the vessel wall at this location should be smooth. If the vessel wall consists of multiple layers, the layers must be in close contact, with no air bubbles or gas pockets. Examples include vulcanized hard rubber linings, epoxy resin linings, stainless steel linings, and titanium linings.

Intrinsically Safe Ultrasonic Level Sensor Dimensions

Checking Tank Trucks for Residual Fuel Before Loading

Our Portable Intrinsically Safe Ultrasonic Level Sensor is a liquid level detection device specifically designed for tank trucks. It is used to check whether there is any residual liquid in the tank truck before it enters the tank farm to be filled with liquid.

When using the portable level detector to measure the liquid level in a tank truck (or container), first connect the probe via the cable to the aviation connector socket on the top of the main unit, and tighten the nut on the connector plug. The operator holds the main unit in one hand and places the probe end flush against the bottom surface of the tank truck (or container) with the probe pointing vertically toward the liquid surface. Use the buttons to calibrate the device and measure the liquid level status.

Checking Tank Trucks for Residual Fuel Before Loading

Our Portable Intrinsically Safe Ultrasonic Level Sensor offers two liquid level measurement modes: liquid level value mode and liquid level status mode. In liquid level value mode, the probe is positioned against the bottom of the tank to measure the height of the liquid inside. In liquid level status mode, the probe is mounted on the side of the tank to detect and indicate whether liquid is present at the probe’s location.

Mode 1: Liquid Level Value Measurement Mode

In Liquid Level Value Measurement Mode, you must first ensure that the probe is installed at the bottom of the tank. Our main unit can display the liquid level value, liquid level percentage, and temperature. Our Portable Intrinsically Safe Ultrasonic Level Sensor is factory-calibrated. If the medium you are measuring matches the medium confirmed at the time of order, no further calibration is required. Simply press the function key on the main screen to measure the liquid level.

If the medium being measured changes, or if you press the function key and no liquid level value is detected for an extended period, you will need to enter the menu screen to calibrate the instrument.

  1. Confirm that the probe is properly attached;
  2. Set the measurement range: it should be greater than or equal to the tank’s capacity;
  3. Set the default sound speed: the sound speed of the medium being measured;
  4. Select “Automatic Calibration” and wait for the instrument to complete the process.

Mode 2: Liquid Level Status Measurement Mode

In liquid level status measurement mode, simply mount the probe on the side of the tank, against the outer wall at the point to be monitored. The main unit of our Portable Intrinsically Safe Ultrasonic Level Sensor will indicate whether liquid is present at the measurement location. Similarly, if the measured medium matches our factory calibration, no calibration is required.

If the medium changes or the measurement status is incorrect, you will need to access the menu interface to calibrate the instrument.

  1. Confirm that the probe is properly attached;
  2. Set the liquid level status: the liquid level status at the probe’s location;
  3. Perform calibration using the current calibration menu and wait for calibration to complete.
Portable Intrinsically Safe Ultrasonic Level Sensor for Tank Trucks

FAQ

The Intrinsically Safe Portable Ultrasonic Level Sensor is somewhat similar to our portable ultrasonic liquid level indicator. However, the Intrinsically Safe Portable Ultrasonic Level Sensor offers more advanced functionality; it not only detects the presence or absence of liquid but also measures the exact liquid level. It is, however, only compatible with wall thicknesses of 2–10 mm.

Of course, the Portable Ultrasonic Liquid Level Indicator also has its specific applications—it is designed for CO₂ and fire extinguishing agent cylinders with wall thicknesses up to 30 mm. However, it cannot measure the exact liquid level.

Our Portable Intrinsically Safe Ultrasonic Level Sensor uses a built-in potted lithium-ion battery pack (18650/3500 mAh), providing a continuous operating time of more than 8 hours.

No, charging, disassembling, or replacing the battery in a hazardous area is strictly prohibited.

Yes. Our Portable Intrinsically Safe Ultrasonic Level Sensor main unit is rated Ex ib IIB T4 Gb, and the probe is rated Ex mb II T6 Gb, making it suitable for Zones 1 and 2 in Groups IIA/IIB and Temperature Classes T1–T4.

Yes. Our Portable Intrinsically Safe Ultrasonic Level Sensor can measure LPG or propane tanks.

Yes, our Portable Intrinsically Safe Ultrasonic Level Sensor can measure gasoline, diesel, and edible oil. However, when changing the medium, you’ll need to reset the sound velocity or use the “Automatic Measurement Calibration” feature.

Our Portable Intrinsically Safe Ultrasonic Level Sensor is designed for horizontal tanks, requiring that the inner and outer walls at the probe location be flat. If your tank is tilted or uneven, please contact our sales engineers for confirmation.

The Portable Intrinsically Safe Ultrasonic Level Sensor requires that the tank be made of a rigid material capable of effectively transmitting signals. Examples include carbon steel, stainless steel, fiberglass, epoxy, hard plastic, ceramic, glass, and hard rubber. For multi-layered walls, the layers must be tightly bonded without air bubbles or gas pockets.

There are three common methods: opening the manhole to measure with a dipstick, checking the signal from the vehicle-mounted residual liquid sensor, or detecting from outside the tank.

Using a dipstick requires opening the manhole, which exposes the operator to vapors.

The vehicle-mounted residual liquid sensor can only be used if the tank truck is equipped with one.

Our Portable Intrinsically Safe Ultrasonic Level Sensor corresponds to the third method.

Before the tanker enters the tank farm, attach the probe to the outer wall at the bottom of each compartment. Press the function key on the main unit once, and the screen will display the liquid level inside the compartment. The entire process requires no opening of the tank cover or contact with the fuel.

Operating Conditions:

  • Tank wall thickness: 2–10 mm; the inner and outer surfaces of the tank wall at the probe location must be smooth;
  • Media: gasoline, diesel, edible oil, etc.;
  • The main unit is intrinsically safe (Ex ib IIB T4 Gb), and the probe is encapsulated (Ex mb II T6 Gb), making it suitable for use in Zones 1 and 2.

There are two main risks: First, filling the tank to its full capacity may cause overflow. Second, if different types of fuel are present, it may lead to cross-contamination.

Our Portable Intrinsically Safe Ultrasonic Level Sensor is a standard product. After you place your order, we perform factory testing and calibration according to your specified parameters. Shipment typically takes 3–5 business days.

We provide a one-year warranty for the Portable Intrinsically Safe Ultrasonic Level Sensor.

Further Reading

    Request For Quote