SI-3303 digital steam vortex flow meter is a flow meter operating with Karman Vortex principle for flow rate of steams (saturated steam, superheated steam, etc.). It could be used in automatic control system as flow transmitter.
SI-3303 steam flow meter is also with unique sensor encapsulation and protection technology to ensure service life of the sensor.
Diameter | DN200~DN3000mm |
Accuracy | 0.5% to 2.0% of reading |
Temp. range | -20~+150℃ |
Pressure | 1.6 MPa |
Flow rate | 0.5~6m/s |
Straight pipe required | Up stream≥5DN, down stream≥3DN |
Features
Specifications
Order Guide
Applications
Reviews
Features
- Without movable parts and adopt simple structure, easy to install and maintain.
- The product is with stable performance and no zero drifting, offering pipe and insertion sensor type options.
- Wide measurement range, the highest range ratio could reach to 20:1
- Low pressure loss and consumption.
- Assemble with anti-interference circuit and anti-vibration sensors, which could ensure anti-vibration performance of the product.
Specifications
Medium | Saturated steam, superheated steam, etc. |
Accuracy | Pipe type: Class 1.0 |
Insertion type: Class 2.5 | |
Medium temperature | -40℃~+400℃ |
Nominal pressure | ≤1.6Mpa (offer ≤2.5Mpa and ≤4.0Mpa customization) |
Flow rate | 5-60m/s |
Output | Voltage pulse, 4-20mA output, HART, Modbus, RS485, RS232 options. |
Installation | Flange, clamp flange, insertion, threat, clamp connection |
Power | 12~28VDC |
3.6V lithium battery (on site display) | |
85~265VAC (Remote display) | |
Operating condition | Temperature: -25℃~60℃ |
Humidity: 5%~90% | |
Housing material | 1Cr18Ni9Ti |
Order Guide
In addition to regular products, we support customization
SI-3303- | Note | |||||||||||
Nominal diameter | DNXX | DN15~DN1800 (mm) | ||||||||||
Structure | F | Remote type with display | ||||||||||
Y | Compact type with display | |||||||||||
Accuracy | A | Pipe type: Class 1.0 | ||||||||||
B | Insertion type: Class 2.5 | |||||||||||
Nominal pressure | 16 | 1.6Mpa | ||||||||||
XX | Customization | |||||||||||
Medium | S | saturated steam | ||||||||||
O | superheated steam | |||||||||||
The temp. of medium | M | <250℃ | ||||||||||
H | >250℃ | |||||||||||
Other function | P | With pressure compensation | ||||||||||
T | With temperature compensation | |||||||||||
PT | With pressure and temperature compensation | |||||||||||
Power supply | 1 | 12~28VDC | ||||||||||
2 | 3.6V lithium battery (on site display) | |||||||||||
3 | 85~265VAC (Remote display) | |||||||||||
Output signal | A | 4-20mA | ||||||||||
M | Voltage pulse | |||||||||||
H | HART | |||||||||||
R1 | RS232 | |||||||||||
R2 | RS485 | |||||||||||
Installation | 1 | Flange | ||||||||||
2 | Clamp flange | |||||||||||
3 | Insertion | |||||||||||
4 | Thread | |||||||||||
5 | Clamp | |||||||||||
Explosion proof | A | No explosion proof | ||||||||||
B | Intrinsic explosion proof | |||||||||||
G | Flame proof |
Applications
Saturated steam, superheated steam, etc.
Reviews
May 11, 2019 at 09:08 pm
Lily
The Temperature and pressure compensation really works well.