Home > Blog > SCFM (Standard CFM) vs. ACFM (Actual CFM) and Calculator

SCFM (Standard CFM) vs. ACFM (Actual CFM) and Calculator

SCFM (Standard CFM) vs. ACFM (Actual CFM) for gas flow meter

SCFM (Standard CFM) and ACFM (Actual CFM) are commonly used units for measuring gas flow rate. For example, in the air compressor industry, they are used to measure airflow and air consumption. So what are the differences between them? How should they be converted?

Both SCFM and ACFM are based on CFM. CFM is a commonly used unit for gas flow rate, representing the number of cubic feet passing through per minute. It is mainly used to measure the volumetric flow rate of gas passing through per unit time.

In the International System of Units (SI), we usually use cubic meters per hour (m³/h) to express gas flow rate, while in the Imperial System, CFM is the commonly used representation. Specifically, 1 CFM equals 28.316846592 liters per minute (L/min), or 0.028316847 cubic meters per minute (m³/min).

However, CFM is affected by parameters such as altitude, temperature, and elevation, leading to the development of SCFM, ACFM, and IFCM.

What is SCFM?

SCFM, or standard cubic feet per minute, is the flow rate of a compressor under standard conditions. This is a very common measurement method when comparing compressors, allowing for “same-class” evaluations. Keep in mind that standard conditions are difficult to meet in real life, but it is still a more practical measurement method because it allows for fair comparisons between compressors.

SCFM is widely used in industrial, chemical, and engineering fields to measure gas flow rate.

What is ACFM?

However, in actual measurements, the temperature, pressure, and other parameters are not exactly the same as in standard operating conditions. Therefore, the actual gas flow unit, ACFM, was developed.

ACFM is actual cubic feet per minute. This means it describes the actual flow rate considering environmental conditions. While this measurement may more accurately describe the actual gas flow rate, it is illogical to specify a compressor/gas flow meter based on ACFM due to the extremely wide range of possible environmental conditions.

Therefore, most of the time, when purchasing a compressor or gas flow meter, we need to convert the ACFM under actual operating conditions to SCFM under standard operating conditions. You can also use our online calculator.

Online Calculator

Industrial Gas Flow Converter

Professional tools for ACFM, SCFM, and m³/h calculations.

Actual vs Standard
Imperial to Metric
Conversion Factor: 1 SCFM = 1.608 Nm³/h
(Standardized to 14.7 PSIA & 60°F)

Data based on Ideal Gas Law & ISO 1217

FAQ

SCFM is a description of gas flow rate under standard conditions and can be used to compare the performance of different devices, such as air compressors and gas flow meters.

ACFM is the actual gas flow rate and is used when it is necessary to determine pipe diameter, valve size, or filter specifications. Ensure that the selected components can meet the actual gas flow rate requirements under specific, non-standard operating pressures and temperatures.

No, not necessarily. Whether SCFM or ACFM is higher depends on the gas pressure and temperature conditions.

Given the known ACFM value and the actual temperature and pressure, you can convert ACFM to SCFM using the following formula:

SCFM = ACFM × (294.26 / (temperature + 273.15)) × ((14.7 + pressure) / 14.7)

More Reliable Compressed Air and Gas Flow Meters

Piezoelectric Pressure Transducer – Quartz, Threaded Mount

The SI-YD205 Piezoelectric Pressure Transducer is an M10 × 1 threaded-mount pressure transducer. Utilizing a quartz crystal as the piezoelectric element, it offers a wide frequency response and high rigidity, with a pressure sensitivity of approximately 100 pC/MPa. The SI-YD205…

OEM 80GHz Radar Level Sensors for Private Labeling

During OEM business negotiations, the customer requested OEM private-label 80GHz radar level transmitters, with an annual purchase volume of approximately 2,500 units. As the original manufacturer, we offer two OEM product lines of 80GHz radar level transmitters for the customer…

Portable Doppler Area Velocity Flow Meter

The Portable Doppler Area Velocity Flow Meter is a specialized device for measuring flow velocity and flow rate in open channels and various types of pipes. Unlike electromagnetic flowmeters, it does not require cutting into the pipe to install a…

How to Adjust a Pressure Switch

How to Adjust a Pressure Switch? This is a common question among the vast majority of pressure switch users. Whether it’s a mechanical or electronic pressure switch, there are three adjustable parameters: the set point (cut-out), the reset point (cut-in),…

Sino-Inst has many years of experience in gas measurement services. If you have any questions about gas measurement and product selection, please feel free to contact us!

Want to see more of our engineering guides in Google Search? Add Sino-Inst as a preferred source.