Portable Doppler Area Velocity Flow Meter

The Portable Doppler Area Velocity Flow Meter is a specialized device for measuring flow velocity and flow rate in open channels and various types of pipes. Unlike electromagnetic flowmeters, it does not require cutting into the pipe to install a segmented sensor; nor does it require the use of a flow-interception device; and it certainly does not require the installation of a fixed weir to direct the water flow through a fixed outlet. It can measure both clear and turbid water and also solves the challenge of “non-full-pipe measurement.”
The Portable Doppler Area Velocity Flow Meter measures flow velocity based on the ultrasonic Doppler effect and integrates a pressure sensor to measure water level, a temperature sensor to measure water temperature, and a six-axis gyroscope to determine its installation orientation. The housing is made of PVC plastic, providing effective waterproof sealing. It is powered internally by a 7.4V rechargeable battery.
Features
Technical Specifications
| Parameter | Specification |
|---|---|
| Measuring principle | Ultrasonic Doppler (velocity) + pressure sensor (water level) |
| Velocity range | 0.02 – 10 m/s |
| Velocity accuracy | ±2.0% ±1 mm/s |
| Water level / depth range | 0.05 – 10 m |
| Level accuracy | 0.5% ±0.5 cm |
| Water temperature range | -10 – 60 °C |
| Temperature accuracy | ±0.1 °C |
| Instantaneous flow range | 0.001 – 999,999 m³/h |
| Totalized flow range | 0.001 – 999,999,999 m³ |
| Working water depth | 0.1 – 5 m |
| Data update interval | 1 – 10 s (depends on flow conditions) |
| Attitude sensor | 6-axis gyroscope; roll / pitch / yaw ±180° |
| Channel section types | Rectangular, trapezoidal, U-shaped, pipe, custom |
| Display | Large color screen, text + graphics |
| Data storage | 9,999 records |
| Data output | RS232 (DB9), USB-to-RS232 cable; client app with real-time velocity curves and spreadsheet export |
| Power supply | Built-in 7.4 V rechargeable battery (6.5 – 8.2 V DC) |
| Current consumption | < 200 mA |
| Charger | 220 V AC |
| Sensor housing | PVC |
| Protection rating | Sensor: IP68 / Handheld unit: IP65 |
| Sensor cable | Vented cable |
| Handheld connectors | 2-pin (charging), 4-pin (sensor) |
| Applications | Sewers, partially filled pipes, irrigation channels, irregular rivers, streams, discharge outlets |
| Standard package | Doppler velocity sensor, handheld unit, charging cable, RS232 cable, user manual, measuring rod set, carrying case |
Standard package: Doppler velocity sensor ×1, handheld unit ×1, charging cable ×1, RS232 cable ×1, user manual ×1, measuring rod set ×1, carrying case.

Doppler Area Velocity Flow Meter Working Principle
The Doppler effect is named in honor of the Austrian physicist Christian Johann Doppler. In the field of acoustics, when there is relative motion between a sound source and a receiver (i.e., a probe and a reflector), the frequency of the echo changes. This change in frequency is called frequency shift, also known as the Doppler effect.
The Doppler Area Velocity Flow Meter is a multi-point, multi-layer flow velocity analyzer developed using today’s most advanced signal processing technology. Its most notable feature is the ability to be installed as needed on the side, bottom, or top of the river or channel being measured. The transmission angles—upward, downward, left, or right—can be freely adjusted according to on-site conditions, thereby accurately measuring flow velocities at different depths from the riverbed to the water surface and at different distances from left to right. Based on multiple flow velocity data points, the system calculates the average flow velocity.
Based on on-site water level surveys, it can easily calculate the cross-sectional areas of various regular or irregular flow patterns and plot simple reservoir capacity diagrams. This significantly simplifies traditional hydrological flow measurement methods and represents a qualitative leap in accuracy, stability, and real-time performance.
For any river or canal, a single Doppler flowmeter is sufficient to accurately measure the flow pattern distribution, velocity data, and discharge.

Channel Section Types
Five section types can be selected in the Section menu of the handheld unit. Enter the dimensions for the selected type:
- Rectangular: bottom width (D), water level (H), sediment level (h)
- Trapezoidal: bottom width (D), water level (H), sediment level (h), slope (A)
- U-shaped: bottom width (D), water level (H), sediment level (h), slope (A), arc height (d)
- Pipe: diameter (D), water level (H), sediment level (h)
- Custom: 10 points for an irregular section

Display
The main screen shows flow velocity, water level, water temperature, section area, instantaneous flow and totalized flow, together with the date and time. The menus at the top are Section, Settings and Records.
Press MENU on the main screen to switch to the attitude sensor screen. It shows the roll, pitch and yaw angles of the sensor, each from -180° to +180°.

Installation and Connection
- Before first use, fully charge the battery. Plug the charger into the 2-pin charging socket on the handheld unit and into a 220 V AC outlet. Charging is faster when the handheld unit is switched off.
- Place the Doppler sensor in the water.
- Insert the 4-pin plug of the sensor cable into the 4-pin socket on the handheld unit and tighten it.
- Press ON. Select the section type and enter its dimensions in the Section menu.
- Press MENU to check the roll, pitch and yaw angles of the sensor.

Featured Applications
Portable Doppler Area Velocity Flow Meter
Compact and lightweight, it can be operated with one hand and is suitable for a variety of environments, including open channels, pipes, natural waterways, and tidal zones. With strong interference resistance, it operates stably even in environments with complex electromagnetic fields and turbulent water flow. Whether for flow verification by water resources departments, wastewater monitoring by environmental protection agencies, or fluid experiments at research institutions, this device provides reliable support.
It is commonly used in water conservancy, urban underground pipeline networks, urban sewer drainage, industrial wastewater discharge, hospital wastewater, mining and metallurgy, agricultural irrigation, aquaculture, and natural river monitoring, among other applications.
More Flow Measurement Solutions
Sewage Flow Meters and Effluent Flow Meters for Wastewater
Ultrasonic Flow Meters: Doppler Effect vs Transit Time
What Is the Flow Rate? Velocity vs Flow
Irrigation Flow Meters-Indispensable for Modern Agriculture and Irrigation
What is an IP rating? IP65-IP67-IP68

Zhang Wei, possesses 20 years of experience as an automation instrumentation engineer, specializing in the research, design, installation, commissioning, and maintenance of automation instruments.
Face to various instrument communication protocols (such as Modbus, Profibus, etc.), with solid hardware circuit design and software programming skills (proficient in C language and PLC programming). Has extensive project experience; projects he has led and participated in have all achieved outstanding results, improving product accuracy, reducing costs, and increasing production efficiency.
Possesses excellent communication and coordination skills and a strong team spirit, enabling him to quickly respond to customer needs and provide high-quality automation instrumentation solutions.