UHZ-F Magnetic Level Indicator for Corrosive Liquids

UHZ-F Magnetic Level Indicator for Corrosive Liquids

Corrosion-resistant magnetic level indicator is used for measuring the level of various corrosive and toxic liquids in storage tanks during industrial production. It is particularly suitable for acidic and alkaline solutions with low operating temperatures and pressures. The liquid-contacting parts of this level gauge are made of PP or PVC material, and can also be made of stainless steel lined with PTFE using a stretching process. The entire display has no blind spots, is safe and reliable, and has a long service life.

Features

  • Resistant to corrosion from most organic and inorganic acids, alkalis, and salts.
  • Special materials available: PP, UPVC, PPH, PVDF, CPVC, 304 with PTFE lining or PTFE coating.
  • Features simple structure, easy installation, and low maintenance costs.
  • Utilizes a float as the measuring element, with a magnet driving the flip-column display—no power source required.
  • Equipped with upper/lower limit switch outputs for remote alarm and limit control.
  • When paired with a transmitter, enables remote level indication, detection, and control.

Technical Parameters

Applicable LiquidsDensity0.45~2g/cm3
Viscosity≤200cp
Measurement ParametersMeasuring RangeSingle section 200~4000mm, multi-section structure up to 20m or more
Accuracy±5mm or ±10mm
Material and SpecificationsFloatPP, Φ50, wall thickness 4.2mm; 304/316L inner lining F4(PTFE)/F46(FEP), φ57
FloatPP; 304 outer lining F46(FEP)
Flip IndicatorAll-aluminum flap, PA66 nylon flap, glass cover (standard), acrylic sheet optional
Operating EnvironmentProcess Pressure-0.1~1.6MPa
Process Temperature≤120℃
Ambient Temperature-40~80℃
Signal OutputSwitch SignalMagnetic switch: 220V AC 3A, SPDT
Continuous SignalReed remote transmitter: 4~20mA
Process ConnectionsConnection MethodFlange, size according to customer requirements
Process MaterialPP; 304/316L inner lining F46
End AccessoriesUpper ExhaustFlat welded head/flange
Lower DrainageStandard configuration with lower drain valve

Featured Applications

The corrosion-resistant magnetic level indicator is particularly suitable for measuring the level and interface of corrosive liquids with relatively low requirements and cost sensitivity.

The side-mounted, lined magnetic level indicator (PTFE) is suitable for level measurement in corrosive media at high operating temperatures. It employs an advanced stainless steel liner with PTFE stretching and flanging technology, resulting in a reliable structure and long service life. It is the preferred choice for level measurement of highly corrosive media such as hydrofluoric acid.

The lined magnetic level indicator is available with F4 (PTFE) or F46 (FEP) lined floats. The F4 (PTFE) liner is suitable for level measurement of most highly corrosive liquids; the F46 (FEP) liner is suitable for level measurement of highly penetrating and highly corrosive liquids, such as liquid chlorine and bromine.

The PP type magnetic level indicator is a commonly used corrosion-resistant level gauge. For the same measurement range, it weighs only about 1/5 of a standard magnetic level gauge, greatly facilitating on-site installation. It is suitable for electrochemical water treatment, sewage treatment, printing and dyeing industries, as well as for measuring other acidic media immiscible with PP.

PP Material Magnetic Level Indicator for Corrosive Liquids

Application Scope of Corrosion-Resistant Materials

CodeNameApplication Scope
PVCPolyvinyl ChlorideSewage, mildly corrosive liquids
PPPolypropyleneResistant to acids, alkalis, greases, oils, and oil-based agents
PEPolyethyleneResistant to dilute acids, alkalis, alcohols, gasoline, solvents
PTFEPolytetrafluoroethyleneResistant to all chemicals
PVDFPolyvinylidene ChlorideResistant to oils, greases, acids, alkalis, solvents
PURPolyurethaneResistant to fuels, hot oils, and oil-containing liquids
PAPolyamideResistant to oils, greases, solvents

More Level Indicators

Sulfuric Acid Storage Tank Level Measurement

In industries such as chemical engineering, metallurgy, pharmaceuticals, electroplating, and sulfuric acid storage and transportation, sulfuric acid, as a basic raw material, is extremely corrosive. 98% concentrated sulfuric acid is…

Liquid Nitrogen Cryogenic Tank Level Monitoring

When using liquid nitrogen tanks, it’s crucial to constantly monitor the liquid nitrogen level inside. Replenishing the tank as needed ensures the sample remains at a constant -196°C, preserving its…

What are Capacitive Level Sensors?

Capacitive level sensors are a crucial technology for monitoring the level of liquids and solid powders. Capacitive level sensors are a type of level transmitter that can be used for…

Sino-Inst’s corrosion-resistant magnetic level indicators are suitable for measuring the liquid level and interface of liquids in containers. In addition to local indication, they can be equipped with remote transmitters and alarm (control) switches, offering comprehensive indicating functions. They feature a wide measuring range, are not limited by the height of the storage tank, and the indicating mechanism is completely isolated from the measured medium. They offer excellent sealing, high reliability, and safe operation.

We support customization of various materials, such as PP, UPVC, PPH, PVDF, CPVC, 304 stainless steel with PTFE lining, or PTFE coating. Please feel free to contact our sales engineers!

    Request For Quote