ZD10 Series Small Electromagnetic Flow Meter

ZD10 Series Small Electromagnetic Flow Meter

ZD10 Series Small Electromagnetic Flow Meter is a new generation of small-caliber electromagnetic flowmeter specially developed by our company for small flow.

It is widely used in the measurement of desulfurization and denitrification of ammonia water and urea solution, laboratories, small test equipment, chemicals, food, medicine, etc.

Features

  • It has a powerful self-diagnosis function and PFA and F46 linings.
  • It has a flange, sanitary quick-connect, thread, and other interfaces.
  • It has 316L, titanium, Hastelloy, tantalum, platinum-iridium alloy, and other electrodes.
  • Integrated ground electrode design.
  • The highest accuracy is 0.5%, repeatability is 0.15%,
  • The sensor housing is all 304 design, compact, and corrosion-resistant.
  • Good reliability. The performance is better than similar products.
  • The diameters are DN10, DN8, DN6, DN5, DN4, DN3, DN2;
  • No pressure loss; insensitive to vibration;
  • Simple installation and debugging: high measurement accuracy and wide measurement range.

Small Electromagnetic Flow Meter Technical Parameters

DiameterDN2-DN10
Maximum accuracyDN2-4(1%), DN5-8(0.5%), DN10(0.25%)
RepeatabilityDN2-4(0.3%), DN5-8(0.15%), DN10(0.08%)
Measurement range-12-12m/s(flow unit can be changed)
Installation methodClamp, flange, thread, clamp
Connection flange standardGB/T9119-2000 or other options
Connection flange diameterDN10 or DN15(DN20,DN25 can be selected)
Pressure1.0MPa~4.0MPa(other pressure can be customized)
Lining materialF46,PFA,(DN10 PTFE optional)
Electrode material316L, Hastelloy, Titanium, Tantalum, Platinum
Electrode formStandard
Sensor protection levelIP65 standard, IP67, IP68 (optional only for sensors)
Medium conductivity>5μs/cm (water>20μs/cm)
Medium maximum temperature≤90℃,
Ambient temperature-25℃~+65℃
Converter installation methodOne-piece, split
Output signal4-20mA current signal, frequency/pulse output
Power supplyAC:85V~265V,DC:18V~36V
Self-diagnosisYes
Empty and full pipe, zero calibrationYes
CommunicationRS485/Modbus, HART
Explosion-proofNon-explosion-proof/EXdIICT5
LanguageChinese, English
Product implementation standardJB/T9248-1999
Small Electromagnetic Flow Meter details

Flow Range

DNMeasurable flow range
Flow rate 0.3~12m/s
Minimum flow rate to ensure accuracy
Flow rate 0.5m/s
Maximum flow rate to ensure accuracy
Flow rate 12m/s
DN23.4-135 L/h5.7 L/h135 L/h
DN37.6-305 L/h12.7 L/h305 L/h
DN413.6-543 L/h22.6 L/h543 L/h
DN521.2-848 L/h35.3 L/h848 L/h
DN630.5-1221 L/h50.9 L/h1221 L/h
DN854.3-2171 L/h90.5 L/h2171 L/h
DN1084.8-3393 L/h141.4 L/h3393 L/h

Dimensions

ZD10 Series Small Electromagnetic Flow Meter Dimensions
FlangeLength LFlow meter heightFlow meter weight
DN10200mm320mm6.55kg
DN15200mm320mm6.70kg
DN20200mm320mm6.85kg
DN25200mm320mm7.00kg

ZD10 Series Small Electromagnetic Flow Meter Order Guide

ModelZD10
Installation methodFlange typeF
Threaded typeM
Sanitary typeK
Clamp-on typeW
LiningF46F
PFAP
PTFET
CeramicsC
OthersZ
DiameterDN202
DN303
DN404
DN505
DN606
DN808
DN1010
Electrode316LS
TitaniumM
Suitable alloysH
TantalumT
Platinum-iridium alloyP
Pressure level1.0MPaC
1.6MPaD
2.5MPaE
4.0MPaF
OthersZ
Material3042
3163
Others0
Structural formIntegratedT
SplitR
Communication4-20mA1
4-20mA+HART2
4-20Ma+MODBUS3
No output5
Power supply220VACG
24VDCK
Battery poweredY
Protection levelIP650
IP67(Only sensor)1
IP68(Only sensor)2
Explosion-proofNon0
YesEX
ZD10 Series Small Electromagnetic Flow Meter Integrated and Split Type

Other functions and parameters

Instrument power consumption: ≤15W.

Self-diagnosis: The converter can confirm whether the hardware is normal, perform fault diagnosis, and prompt on the converter. (Commonly used are empty and full pipe detection alarms and excitation detection alarms)

Interchangeability: The converter can be used interchangeably with sensors of various calibers. The converter can be configured on-site, and replacing the converter will not affect the characteristics of the system. Low-frequency excitation and high-frequency excitation.

Small Electromagnetic Flow Meter DN3

Display content: forward total flow, reverse total flow, flow rate, alarm, current output value, etc.

Implementation standards

Manufacturing standards: in accordance with the National Bureau of Machinery Industry’s Standard Industry Standard of the People’s Republic of China (JB/T9248-1999) – Electromagnetic Flowmeter

The inspection and testing standards are in accordance with the National Quality Inspection Regulations of the People’s Republic of China (JJG164-2000) – Liquid Flow Standard Device issued by the State Administration of Quality and Technical Supervision and the National Standard of the People’s Republic of China (GB4451-84) – Industrial Automation Instrument Vibration (Sine) Test Method approved by the National Bureau of Standards.

More Featured Flow Measurement Solutions

ZD10 Series Small Electromagnetic Flow Meter can be configured in one-piece or split type. It is specially designed for measuring small-diameter and small-flow. Made of 304 stainless steel, compact and corrosion-resistant. It can measure sewage, hydrochloric acid, sulfuric acid, mud, etc.

Sino-Inst supports parameter customization of micro electromagnetic flowmeters. Optional pulse output, 4-20mA current output, RS485 remote communication. You can choose flange, thread, clamp and other connections.

If you need to purchase a small-diameter electromagnetic flowmeter, or have related technical questions, please feel free to contact us.