General Purpose Ultrasonic Level Meter for Liquids

General Purpose Ultrasonic Level Meter for Liquids

General Purpose Ultrasonic Level Meter is suitable for continuous liquid level measurement of various storage tanks and pools in non-flammable and explosive gas environments. Suitable for installation in large pools, water tanks, drainage ditches, storage tanks, pools, etc.

Our Sino-Inst General Purpose Ultrasonic Level Meter supports two-wire or four-wire 4-20mA signal output. Connect display instruments, PLC and various DCS systems to provide real-time liquid level data for industrial automation operations. And anti-corrosion materials are optional.

Features of General Purpose Ultrasonic Level Meter

  • Brand new appearance, high waterproof, sun protection function design.
  • The patented sonic intelligence technology software can perform intelligent echo analysis without any debugging or other special steps. This technology has the functions of dynamic thinking and dynamic analysis.
  • The liquid level accuracy reaches ±0.5%. Able to resist various interference waves.
  • This instrument is a non-contact instrument and does not come into direct contact with liquid, so the failure rate is low.
  • The instrument provides a variety of installation methods, and users can fully calibrate the instrument through this manual.
  • All input and output lines of the instrument are protected against lightning and short circuit.

Technical parameters

Measuring range5m 10m, 15m
Transducer materialGeneral: ABS
Anti-corrosion: PVDF
Blind Area≤0.3m (5m/10m)
≤0.6m (15m)
Resolution0.5% of the set range of earth
Beam angle6°(5m range)
8°(10m range)
10°(15m range)
Error≤1%
DisplayLCD display
Input Rated Voltage85~264VAC50/60Hz
18~30VDC
Output Type2-wire system 4~20mA
4-wire system 4~20mA
Optional: RS-185/relay output
Relay contact capacity4A 250V AC/30V DC
Ambient temperature-20~60℃
Process temperature-20~80℃
Process pressureAtmospheric pressure
Cable InterfaceM20×1.5
Process connectionThread
Flange
Protection classIP65/IP66/IP67

General Purpose Ultrasonic Level Meter installation method

In an open environment, the bracket installation method is generally used, and the instrument is fixed with its own screw ring. Or directly drill a 60mm diameter round hole on the top of the tank or the top of the lid. Put the meter in and tighten the coil from bottom to top. The installation must ensure that the probe surface of the instrument is level with the liquid level being measured.

As shown in the figure, the probe of the instrument emits sound waves that hit the liquid level and then reflect back to the probe. After receiving the signal, the probe calculates the time from sending to receiving the wave, and obtains the measurement distance H. The current liquid level L is obtained by subtracting the measuring clearance H from the instrument installation height TH.

The instrument range refers to the distance that the instrument can measure. The installation height TH should be less than
range.

The blind zone of the instrument refers to the area where the instrument cannot measure near the probe. The distance between the maximum liquid level and the probe should be greater than the blind zone. For example, if the blind zone is 0.5m, then the distance between the maximum liquid level and the probe must be greater than 0.5m.

For example: measuring range: 6 meters, blind zone: 0.45 meters, actual measured maximum liquid level: 0~5.55 meters.

Probe hair is a diffusion process, that is, it has a direction angle. Be careful when installing, otherwise it may hit the protrusions on the pool wall or the edge of the channel.

General Purpose Ultrasonic Level Meter installation method
General Purpose Ultrasonic Level Meter Installation Guidelines

General Purpose Ultrasonic Level Meter Installation Guidelines

  • The distance from the probe emission surface to the lowest liquid level should be smaller than the measuring range of the optional instrument.
  • The distance from the probe emission surface to the highest liquid level should be greater than the blind area of the optional instrument.
  • The emitting surface of the probe should be parallel to the liquid surface.
  • The installation position of the probe should be as far away as possible from the locations directly below the inlet and outlet where the liquid level fluctuates violently.
  • If the pool or tank wall is not smooth, the instrument installation location must be more than 0.5m away from the pool or tank wall.
  • If the distance from the probe emission surface to the highest liquid level is less than the blind area of the optional instrument, an extension tube needs to be installed. The diameter of the extension tube is greater than 150mm, the length is 0.45m~0.60m, it should be installed vertically, the inner wall is smooth, and the opening on the tank should be larger than the extension tube. Tube inner diameter.
  • If there is stirring in the tank and floating objects or foam on the surface of the medium, it is necessary to install a waveguide with a diameter of 150mm or more, with a smooth inner wall, and install it vertically to the bottom of the tank.

More Featured Industrial Level Transmitters and Measurement Solutions

The General Purpose Ultrasonic Level Meter is an instrument commonly used to measure the level of liquids. It determines the height of a liquid by transmitting and receiving ultrasonic signals. In water plants and sewage treatment plants, General Purpose Ultrasonic Level Meter is widely used to measure the level of water and sewage to monitor and control the entire treatment process.

The General Purpose Ultrasonic Level Meter has the characteristics of non-contact measurement. It does not require direct contact with sewage and avoids the problems of contamination and damage in traditional contact level measurement.

Our Sino-Inst General Purpose Ultrasonic Level Meter supports four-wire system or two-wire system 4-20mA signal output. Widely used in liquid level measurement in various fire water tanks, water plants, waste pools, etc. If you need to purchase General Purpose Ultrasonic Level Meter for liquids, or have related questions, please feel free to contact us!

    Request For Quote



    General Purpose Ultrasonic Level Meter for Liquids|Sino-Inst

    General Purpose Ultrasonic Level Meter is suitable for continuous liquid level measurement of various storage tanks and pools in non-flammable and explosive gas environments. Suitable for installation in large pools, water tanks, drainage ditches, storage tanks, pools, etc.

    Product SKU: General Purpose Ultrasonic Level Meter for Liquids

    Product Brand: Sino-Inst

    Product Currency: USD

    Product Price: 180

    Price Valid Until: 2029-09-09

    Product In-Stock: InStock

    Editor's Rating:
    5